Sale!

200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V

Original price was: £2,945.00.Current price is: £298.98.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: GK3000-4T1600G Category:

Description

200 hp VFD, 160 kW high quality three phase 240V, 420V, 480V variable frequency drive.

Specification:

Basics Model GK3000-4T1600G/ GK3000-2T1600G
Capacity 200 hp (160 kW)
Shipping weight 90 kg
Dimension 760*390*320 mm
I/O Feature Rated current 304A at 380V ~ 480V, 585A at 220V ~ 240V
Input voltage Three phase 240V /420V /480V AC ±15% (Optional)
Input frequency 50Hz/ 60Hz
Output voltage Three phase AC 0~input voltage
Output frequency 0Hz~1000Hz
Over load capacity 150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control Feature Control mode V/F control;
Sensorless vector control;
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive lightning protection measures

  1. To prevent the destruction of surge voltage, a varistor can be installed to the VFD input terminal, of which the withstand voltage should be lower than the voltage of power module to protect the components not being breakdown.
  2. Use a circuit breaker generated low surge voltage, as well as a varistor.
  3. When the transformer primary side is disconnected, VFD can be disconnected earlier by program control. At the same time, it also needs to be added the relevant varistor protection, through the excitation storage energy calculates resistance value. In addition, main circuit should use special arrester and fuse.

At the same time, VFD is generally equipped with lightning absorption network, mainly to prevent instantaneous lightning intrusion and causing damage. In the actual operation, especially in the case of the power cord overhead, the absorption network alone cannot meet the requirements. In lightning areas, this problem is particularly important. If the power cord is overhead, VFD should install with dedicated lightning arrester at the power wire, or according to specifications bury steel pipe for special ground protection in the distance 20m away from VFD. If the power supply is cable introduction, should manage the control room lightning protection system to prevent lightning damaging equipment.

Reviews

There are no reviews yet.

Be the first to review “200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V”

Your email address will not be published. Required fields are marked *